Expand description
Regulator 3P0 Register
Modules§
- BO_
OFFSET - Control bits to adjust the regulator brownout offset voltage in 25mV steps
- BO_
VDD3 P0 - Status bit that signals when a brownout is detected on the regulator output.
- ENABLE_
BO - Control bit to enable the brownout circuitry in the regulator.
- ENABLE_
ILIMIT - Control bit to enable the current-limit circuitry in the regulator.
- ENABLE_
LINREG - Control bit to enable the regulator output to be set by the programmed target voltage setting and internal bandgap reference
- OK_
VDD3 P0 - Status bit that signals when the regulator output is ok. 1 = regulator output > brownout target
- OUTPUT_
TRG - Control bits to adjust the regulator output voltage
- VBUS_
SEL - Select input voltage source for LDO_3P0 from either USB_OTG1_VBUS or USB_OTG2_VBUS